Statistics of station Münnerstadt, DW4939

Here you can find statistics of the TOA lightning detection station Münnerstadt, DW4939.

  • Id: 841
  • Firmware: 1.6
  • Controller: 10.3
  • Amplifier: 12.3 / 12.3
  • Antenna 1+2: Ferrite rod, length=120mm, shielded
  • Antenna 4+5: Loop, diameter=250mm, windings=20, shielded
  • Comment: (RED) shielded ferrite rods, SKS120N, smal loop; AS3935
  • Other Stations from this User: 745, 841

General statistics of the last hour

  • Station active: no
  • Last active: 2.9 minutes ago
  • Last update: 2.9 minutes ago
  • Last detected stroke: 2024-11-24 04:54:37 UTC

Stroke count

Here you can see the whole stroke count per hours detected by the lightning network, the count of detected strokes/h of the station Münnerstadt, DW4939 and the mean stroke count for all stations

Graphs: Stroke statistics

Signal count

The count of received signals per hour of the station Münnerstadt, DW4939 and also mean value of all stations.

Graphs: Signal statistics

Ratios

Stroke and locating ratios are important parameters for the correct adjustment of the station. Calculations:
locating ratio = (detected strokes of the station) / (signals of the station)
stroke ratio = (detected strokes of the station) / (network stroke count)

Graphs: Locating and stroke ratios

Stroke ratio by distance

Overview about the own locating ratio over distance from stations. Whole stroke count over distance is also visible.

Graphs: Stroke ratio by distance

Stroke ratio by bearing

Own locating ratio over the geographic direction. For better comparision, there is also the whole stroke count visible.